Featuring 3-port isolation, 12.5 mm SIL-rated KC Series from Pepperl+Fuchs can be programmed and configured in field with pushbutton or dip switch logic functions. Units provide limit detection with form C alarm contacts, as well as fault detection and alarm functionality. With spring terminals, cable is inserted in socket and fixed by spring force, and can be released by pressing terminal button. Devices are suited for control rooms with limited space in both hazardous areas and general purpose locations.
These intrinsic safety barriers connect easily with our exclusive PowerRail system. By using PowerRail, a group of safety barriers is energized from an AC or DC source & monitored for group fault conditions. The PowerRail & IS barrier combination allows for simple expansion with no additional wires. You can also design multiple redundant power configurations.
Marshall Wolf Automation, your authorized industrial automation distributor now has extended hours to serve you better! We are here from 7:30am until 6:00pm Central Standard Time! Call us today at 800-325-9653 (WOLF)!










K-System
H-System
E-System
Pepperl+Fuchs
know that Pepperl & Fuchs is a global market leader of industrial safety equipment for intrinsic safety and explosion protection technology. They offer a complete range of solutions for the process automation industry that includes intrinsic safety isolators, zener barriers, signal conditioners, fieldbus technology, remote I/O, Hart interfaces, HMI for hazardous environments, custom cabinets, junction boxes, and separator alarm systems.
46B Ex n Series-The sensors of the 46B series comply with category 3 and have been developed especially for zone 2 ("Gas-Ex") in protection type nA and for zone 22 ("Dust-Ex") in protection type td. They may be used with conducting and non-conducting dust. The sensors are accommodated inside a metal casing for protection against mechanical damage.
Intrinsically safe sensors of the 92 Ex series-These are designed either as a single-beam light barrier, as a reflection light barrier or as a reflection light button, and can detect objects reliably at distances between 300mm and 12 m. The intrinsically safe ATEX sensors communicate the switching signals by way of the NAMUR interface to the VS 403 isolating switching amplifiers. Sensors of this series may be used in zones 1 and 2 in areas where there are potentially explosive gases and dust.
Isolated switching amplifier VS 403 with intrinsically safe supply circuit-The VS 403 isolating switching amplifier makes it possible to effect an intrinsically safe circuit for the sensors of the '92" series. For setting up the intrinsically safe circuit, Leuze electronics also offers blue cables with M12 circular plugs to connect the sensor to the isolating switching amplifier.